The Path
Module 6 · FHIR·12 min
From HL7 v2 to FHIR
Mapping an ORU to an Observation, field by field.
The Leleux Clinic interface engine receives an ORU^R01 from the sleep lab. The patient app wants FHIR. Someone has to decide where each field goes. Good news: HL7 has published an official guide for exactly that, and we are going to use it.
Here is the starting message:
The sleep lab sends Marie Dubois’s AHI. Click each field of the OBX: each has a precise destination in FHIR.
The official HL7 v2-to-FHIR guide
HL7 publishes the HL7 Version 2 to FHIR guide, version 1.0.0, STU 1 (Standard for Trial Use), built on FHIR R4. It holds three kinds of tables:
- message maps: which message gives which resources;
- segment maps: which field goes into which element;
- vocabulary maps: which v2 code becomes which FHIR code.
It is not law: every project can adapt it. But starting from the guide saves you from reinventing what others have already argued about for years.
Level 1: the message becomes a bundle of resources
For an ORU^R01, the guide gives:
| v2 segment | FHIR resource |
|---|---|
MSH |
Bundle and MessageHeader |
PID |
Patient |
PV1 |
Encounter |
ORC, OBR |
ServiceRequest and DiagnosticReport |
OBX |
Observation, one per OBX |
NTE |
a note in the relevant resource |
The flat message turns into a network of resources linked by references.
Level 2: PID becomes Patient
| v2 field | FHIR element | In our example |
|---|---|---|
PID-3 |
Patient.identifier |
1024, LELEUX record |
PID-5 |
Patient.name |
family DUBOIS, given Marie |
PID-7 |
Patient.birthDate |
1985-03-12 |
PID-8 |
Patient.gender |
F becomes female |
PID-11 |
Patient.address |
(empty here) |
Two details. The date changes format: 19850312 becomes 1985-03-12. And sex goes through a vocabulary table: F from v2 table 0001 becomes female.
Level 2: OBX becomes Observation
This is the heart of the lesson. Click the OBX fields in the message above as you follow this table.
| v2 field | FHIR element | In our example |
|---|---|---|
OBX-2 |
picks the type of value[x] |
NM gives valueQuantity |
OBX-3 |
Observation.code |
local code AHI, then LOINC 69990-0 as alternate |
OBX-5 |
Observation.value[x] |
28.5 in valueQuantity.value |
OBX-6 |
the unit of valueQuantity |
/h |
OBX-7 |
Observation.referenceRange.text |
<5 |
OBX-8 |
Observation.interpretation |
H |
OBX-11 |
Observation.status |
F becomes final |
OBX-14 |
Observation.effectiveDateTime |
2026-06-27T06:30:00 |
OBX-16 |
Observation.performer |
(empty here) |
Three mechanisms to remember.
OBX-2 decides the shape. NM gives valueQuantity. ST would give valueString. CWE would give valueCodeableConcept. That is why a wrong OBX-2 breaks the conversion.
OBX-3 gives two codes. The local code (components 1 to 3) and the alternate code (components 4 to 6) become two coding entries in the same Observation.code.
OBX-6 gives the unit. The guide puts the first component into the Quantity’s code, and the second one, the label, into unit. Here the second one is empty: the engine often copies the code, /h, as the label. The unit system is not written in our message: in v2.5.1, the coding system table does not list UCUM yet (later versions add it). So the interface engine has to know that /h is a valid UCUM unit, “per hour”, and add http://unitsofmeasure.org.
Here is the result:
{
"resourceType": "Observation",
"status": "final",
"code": {
"coding": [
{ "system": "https://fhir.clinique-leleux.example/CodeSystem/labo-sommeil", "code": "AHI", "display": "Apnea-hypopnea index" },
{ "system": "http://loinc.org", "code": "69990-0", "display": "Apnea hypopnea index 24 hour" }
]
},
"subject": { "reference": "Patient/1024" },
"effectiveDateTime": "2026-06-27T06:30:00+02:00",
"valueQuantity": {
"value": 28.5,
"unit": "/h",
"system": "http://unitsofmeasure.org",
"code": "/h"
},
"interpretation": [
{
"coding": [
{ "system": "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation", "code": "H" }
]
}
],
"referenceRange": [{ "text": "<5" }]
}
The subject link to Patient/1024 comes from the PID in the same message. The URI of the local code is written nowhere in the v2: L only says “local”. The engine knows it and adds it. The +02:00 offset is not in OBX-14: the interface engine has to know the time zone and add it.
Vocabulary tables
v2 and FHIR codes are not always the same. The guide provides tables to go from one to the other:
| v2 table | v2 code | FHIR code |
|---|---|---|
| 0085, result status | F |
final |
| 0085 | P |
preliminary |
| 0085 | C |
corrected |
| 0078, abnormal flag | H |
H |
| 0078 | L |
L |
| 0001, sex | F |
female |
Some codes have no counterpart. In table 0085, R (results entered, not verified) or I (specimen in lab) have no direct mapping in the guide: your project has to decide. The guide shows a technique to lose nothing: keep the original v2 code in an extension on status.
OBR becomes DiagnosticReport
| v2 field | FHIR element |
|---|---|
OBR-3 |
DiagnosticReport.identifier |
OBR-4 |
DiagnosticReport.code |
OBR-7 and OBR-8 |
DiagnosticReport.effectivePeriod, start and end |
OBR-22 |
DiagnosticReport.issued |
OBR-25 |
DiagnosticReport.status |
So the polysomnography report gets a period: from 26 June, 10 p.m., to 27 June, 6:30 a.m. Each Observation keeps its own point in time.
Check your understanding
1 of 4In the official v2-to-FHIR guide, where does OBX-5 go when OBX-2 is NM?
+50 XPPass the quiz (3 correct answers) to complete the lesson.
Reviewed and checked on 27 September 2026